Comparing carbon dioxide levels within urban transport microenvironments during rush hour and non-rush traffic

Document
Contributors
Abstract
INTRODUCTION: Commuters spend countless hours within tightly confined spaces with limited ventilation that may be filled with many contaminants. By analyzing if there is a significant difference between levels of carbon dioxide between rush and non-rush hour conditions, it can be determined if some commuters are subjected to poorer levels of air quality during certain times of the day. OBJECTIVES: The primary objective of this study is to understand whether there are significant ventilation deficiencies during rush compared to non-rush hour times in urban transport microenvironments. METHODS: Analysis of urban transport microenvironments was done using the TSI brand QTrak Indoor Air Quality (IAQ) Monitor to gather data on carbon dioxide at 1-minute intervals on the 99 B-line express bus that runs between Broadway and Commercial Skytrain Station and the Broadway and Cambie Street Skytrain Station. RESULTS: A one tailed T-test was done on the NCSS 9 statistical software to compare if rush hour urban microenvironments had significantly higher concentrations of carbon dioxide than when compared to non-rush hour. Statistical analysis determined that since the P-value was well above the alpha level of 0.05 (i.e. P<0.05), it gives reason to accept the null hypothesis, which states that rush hour concentrations were not higher than non-rush hour. CONCLUSION: Statistical analysis determined that the overall concentrations of carbon dioxide during rush hour were not significantly higher than non-rush hour times. This result may have been attributed to conditions and factors during data collection that could not be controlled by the researcher. Due to the length of the route, exposure times were found to be within time-weighted averages as set out by the American Conference of Industrial Hygienists (ACGIH), though it was still not within the recommended limit of 1000 ppm as set out by the American Society of Heating, Refrigeration and Air-Conditioning (ASHRAE). Project submitted in partial fulfillment of the requirement for the degree of Bachelor of Technology in Environmental Health, British Columbia Institute of Technology, 2015.

Refine your search

Note
Project submitted in partial fulfillment of the requirement for the degree of Bachelor of Technology in Environmental Health, British Columbia Institute of Technology, 2015.
Degree granted
Bachelor of Technology (BTech) in Environmental Health
Publisher
British Columbia Institute of Technology
Number of pages
21 pages
Type
Form
Language
Rights
This license enables reusers to copy and distribute the material in any medium or format in unadapted form only, for noncommercial purposes only, and only so long as attribution is given to the creator. CC BY-NC-ND includes the following elements: BY: credit must be given to the creator. NC: Only noncommercial uses of the work are permitted. ND: No derivatives or adaptations of the work are permitted. https://creativecommons.org/licenses/by-nc-nd/4.0/