A performance comparison between FRC and WWM reinforced slabs on grade

Document
Contributors
Abstract
Proceedings of 4th International Conference on Structural Health Monitoring of Intelligent Infrastructure (SHMII-4) 2009, 22-24 July 2009, Zurich, Switzerland. A comparative experimental study was conducted to investigate the effectiveness of fiber reinforcement as a non-corrosive alternative for welded-wire reinforcement in slabs on grade. Six full-scale slabs-on-grade, reinforced with various combinations of WWM (Welded Wire Mesh), polymeric macro-synthetic fibers (PMF) and cellulose fibers were tested under a centrally concentrated load. Their ductility and load carrying capacity were evaluated and compared. Based on the results of this study, it seems that high dosages of polymeric macrofibers can be used to successfully reinforce concrete slabs. Given that the use of PMF eliminates the possibility of corrosion of reinforcement, this may be a superior option. Furthermore, it seems low dosages of fibers act as an ineffective replacement for WWM. Low dosages of PMF and cellulose fiber when added on their own, or in combination with each other were found to be insufficient in providing sufficient ductility or load carrying capacity compared to the control slab when subjected to the load test. Slabs reinforced with cellulose fiber had a poor mechanical response in comparison to WWM and therefore cellulose fiber on its own is not recommended.,Conference paper,Published.

Refine your search

Note
Proceedings of 4th International Conference on Structural Health Monitoring of Intelligent Infrastructure (SHMII-4) 2009
Publisher
ISHMII
Type
Language
Rights
© 2009 Faezeh Azhari, Sudip Talukdar, Nemkumar Banthia